3 Way Valve

Item Specification
Operating voltage (V) 9 - 16
Operating current (A) Max 1.3
Operating condition (°C [°F]) -40 to 115 (-40 to 239 )

Electric Water Pump (EWP)

Item Specification Remark
Type Water pump Brush Less Direct Current (BLDC)
Operating voltage (V) 9 - 16 -
RVWD ON LIN control -
Capacity (ℓ)(V) 1.43 kgf/cm² / 14 LPM(Liter Per Minute) / 13.5 - 14.5 -
Rated current (A) Max 10 -
Max. Current (A) Max 15 -
Operating temperature (°C [°F]) -40 to 135 (-40 to 275) -

Battery Heater

Item Specification
Rated voltage (V) DC 653
Input voltage (V) DC 450 - 774
Heater capacity (kW) 3.8 - 4.2
Ampere (A) Max 7.3
Heater resistance (Ω) 101.65 - 112.35
Operating condition (°C [°F]) -40 to 105 (-40 to 221)

Coolant Temperature Sensor

Item Specification
Operating condition (°C [°F]) -40 to 140 (-40 to 284)

Coolant Temperature Table

emperature [°C (°F)] Resistance (kΩ)
-20 (-4) 14.13 - 16.83
-10 (14) 8.39 - 10.22
0 (32) 5.28 - 6.30
10 (50) 3.42 - 4.01
20 (68) 2.31 - 2.59
30 (86) 1.55 - 1.76
40 (104) 1.08 - 1.21
50 (122) 0.77 - 0.85
60 (140) 0.55 - 0.61
70 (158) 0.42 - 0.45
80 (176) 0.31 - 0.33
90 (194) 0.24 - 0.25
100 (212) 0.18 - 0.19
110 (230) 0.15 - 0.15
120 (248) 0.11 - 0.12

Coolant

Battery Type Coolant Specification
160kW(2WD) 70kW+160kW(4WD)
Standard (ℓ) Normal Coolant (Pink color) 17.7 17.9
Long range (ℓ) 19.4 19.6

Motor Coolant

Battery Type Coolant Specification
160kW(2WD) 70kW+160kW(4WD)
Standard (ℓ) Normal Coolant (Pink color) 6.7 6.9
Long range (ℓ) 6.7 6.9

High Voltage Battery Coolant

Battery Type Coolant Specification
160kW(2WD) 70kW+160kW(4WD)
Standard (ℓ) Normal Coolant (Pink color) 11.0 11.0
Long range (ℓ) 12.7 12.7

    Previous pageHigh Voltage Shut-off Procedures

    High Voltage Shut-off Procedures     • When working on high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of under ...

    PREV

    Next pageTightening Torque

    Tightening Torque Cooling Fan Item N·m kgf·m lb·ft lb·in Cooling fan bolt (LH,RH) 4.9 - 7.8 0.5 - 0.8 3.6 - 5.8 ...

    NEXT
    Other information:

    Kia EV6 (CV) 2022– Workshop Manual: Rear Motor Cover
    Removal     • When working on high voltage system, the work should be performed by technicians who have completed the relevant training. It is because that lack of knowledge of the high voltage system can lead to serious accidents due to electric shock or electric leakage. ...

    Kia EV6 (CV) 2022– Workshop Manual: Roof Side Molding
    Removal 1.Remove the roof side molding (A).     Clip position : Installation 1.Install in the reverse order of removal. ...